Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 118
Filter
1.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550084

ABSTRACT

Abstract This study analyzed the physical-chemical properties of bioactive ionomer materials. Cention N bioactive materials were evaluated chemically activated (CN) and light-cured (CN-LC), Equia Forte Fill (EQUI); conventional resin composite Filtek Z350 XT (Z350); resin glass ionomer cement Riva light Cure (RIVA) and flowable resin composite Filtek Bulk Fill Flow (BULK-F) were evaluated. Sixty specimens (n=10) were prepared for sorption (SR), solubility (SL), flexural strength (FS), shrinkage stress (SS), conversion degree (CD), microhardness (MI), and surface roughness (SR) tests. Non-cured and light-cured materials were assessed on FTIR. 30 human molar teeth were used in the bond strength test (BS). Data were subjected to ANOVA and post-hoc Tukey's test (5% of significance). EQUI showed more sorption in SR and no statistical difference from RIVA and CN-LC. CN group showed more solubility and EQUI presented less (p<0.05). BULK-F showed higher FS (MPa), without differences from CN and Z350, whereas EQUI presented the lowest FS not differing from RIVA. BULK-F and CN-LC showed more shrinkage stress differing from EQUI. CN-LC and CN showed higher CD differing from the other which showed no differences (p>0.05) between them. EQUI showed the highest hardness (p<0.05) in MI. There were no differences (p>0.05) in SR (µm). Z350 and BULK-F presented higher BS, whereas CN-LC showed the lowest, although not differing from EQUI and RIVA. Equia Forte's solubility and microhardness make it a good alternative as a restorative material. Cention N degree of conversion and flexural strength making it an esthetic option to amalgam.


Resumo Este estudo analisou as propriedades físico-químicas dos materiais de ionômero bioativo. Os materiais bioativos Cention N quimicamente ativados (CN) e fotopolimerizados (CN-LC), Equia Forte Fill (EQUI); resina composta convencional Filtek Z350 XT (Z350); resina de ionômero de vidro Riva light Cure (RIVA) e resina composta fluida Filtek Bulk Fill Flow (BULK-F) foram avaliados. Sessenta espécimes (n=10) foram preparados para testes de sorção (SR), solubilidade (SL), resistência à flexão (FS), tensão de contração (SS), grau de conversão (CD), microdureza (MI) e rugosidade da superfície (SR). Os materiais não curados e curados com luz foram avaliados por FTIR. 30 dentes molares humanos foram usados no teste de resistência de união (BS). Os dados foram submetidos a ANOVA e teste de post-hoc Tukey (5% de significância). O EQUI apresentou maior sorção no SR e não mostrou diferença estatística em relação aos grupos RIVA e CN-LC. O grupo CN apresentou maior solubilidade e o EQUI apresentou menor (p<0,05). O BULK-F apresentou maior FS (MPa), sem diferir do CN e do Z350, enquanto o EQUI apresentou o menor FS, não diferindo do RIVA. O BULK-F e o CN-LC apresentaram maior estresse de contração, diferindo do EQUI. O CN-LC e o CN apresentaram maior CD (%), diferindo dos demais, que não apresentaram diferenças (p>0,05) entre si. A EQUI apresentou a maior dureza (p<0,05) no MI. Não houve diferenças (p>0,05) na SR (µm). Z350 and BULK-F apresentaram BS, enquanto a CN-LC apresentou a menor, embora não diferindo da EQUI e da RIVA. A solubilidade e a microdureza do Equia Forte o tornam uma boa alternativa como material restaurador. O grau de conversão e a resistência à flexão do Cention N o tornam uma opção estética ao amálgama.

2.
Vitae (Medellín) ; 30(1): 1-8, 2023-01-22. Ilustraciones
Article in English | LILACS, COLNAL | ID: biblio-1438352

ABSTRACT

Background: Many fish hybrids (i.e., obtained by crossing two species) are produced rather than pure species because of their better growth rate and/or acceptance of formulated feed. However, few studies evaluate and compare their meats and acceptance, including, e.g., for the Amazon hybrid sorubim (Pseudoplatystoma reticulatum x Leiarius marmoratus) and the real hybrid sorubim (Pseudoplatystoma corruscans x L. marmoratus). Objective: Thus, this work aimed to evaluate the physical, chemical, microbiological, and sensory characteristics of fillets from the Amazon and real hybrid sorubins. Method:Proximate composition, instrumental color, water holding capacity, cooking losses, and shear force were measured.Microbiological analyses of the fillets were carried out for Salmonellasp. and Staphylococcusaureus to ensure food safety during sensory analysis. Results: Fillets presented excellent quality, classified in category A (lipids below 5% and proteins between 15 and 20%). There was no significant difference (p>0.05) between the evaluated fillets for several parameters: the average water holding capacities were 33.72 and 34.67%, the cooking losses were 14.93 and 13.41%, the shear forces were 2.21 and 1.74 kgf, and the luminosities were 49.61 and 45.04 for the fillets of Amazonian hybrid sorubim and real hybrid sorubim, respectively. Discussion: There was an evident relationship between water-holding capacities and shear forces. Amazonian hybrid sorubim fillets presented lower intensity of red. However, there was no sensory difference between the hybrids, and both had an acceptance rate above 80%. Conclusion: The hybridization does not alter the characteristics of the fish fillets


Antecedentes: Muchos híbridos de peces (i.e., obtenidos al cruzar dos especies) se producen en lugar de especies puras debido a su mejor tasa de crecimiento y/o aceptación de alimentos formulados. Sin embargo, pocos estudios evalúan y comparan sus carnes y aceptación, incluyendo, p. ej., para lo surubí híbrido amazónico (Pseudoplatystoma reticulatum x Leiarius marmoratus) y lo surubí híbrido real (Pseudoplatystoma corruscans x L. marmoratus). Objetivo: Así, el objetivo de este trabajo fue evaluar las características físicas, químicas, microbiológicas y sensoriales de filetes sorubines híbridos amazónico y real. Método: Se midió composición proximal, color instrumental, capacidad de retención de agua, pierdas por cocción y fuerza de corte. Se realizaron análisis microbiológicos de los filetes para Salmonella sp. y Staphylococcus aureus para garantizar la seguridad alimentaria durante el análisis sensorial. Resultados: Los filetes presentaron una excelente calidad, siendo clasificados en la categoría A (lípidos por debajo del 5% y proteínas entre 15 y 20%). No hubo diferencia significativa (p>0.05) entre los filetes evaluados para varios parámetros: las capacidades de retención de agua fueron 33.72 y 34.67%, las pierdas por cocción fueron 14.93 y 13.41%, las fuerzas de corte fueron 2.21 y 1.74 kgf y las luminosidades fueron 49.61 y 45.04 para los filetes de sorubim híbrido amazónico y sorubim híbrido real, respectivamente. Discusión: Hubo una relación evidente entre las capacidades de retención de agua y las fuerzas de corte. Los filetes de sorubim híbridos amazónicos presentaron menor intensidad de rojo. Sin embargo, no hubo diferencia sensorial entre los híbridos, y ambos tuvieron una tasa de aceptación superior al 80%. Conclusión: La hibridación no altera las características de los filetes de pescado


Subject(s)
Humans , Sense Organs , Physical Phenomena , Fish Products
3.
China Journal of Chinese Materia Medica ; (24): 1866-1875, 2023.
Article in Chinese | WPRIM | ID: wpr-981405

ABSTRACT

According to the method of predicting the physical properties of oily powder based on the additive physical properties of Chinese medicinal powder, Dioscoreae Rhizoma and calcined Ostreae Concha with high sieve rate and good fluidity were mixed and crushed with Persicae Semen, Platycladi Semen, Raphani Semen, Ziziphi Spinosae Semen, and other typical oily materials with high fatty oil content in proportion to obtain 23 mixed powders. Fifteen physical properties such as bulk density, water absorption, and maximum torque force were measured, and the physical properties of typical oily powders were predicted. When the mixing and grinding ratio was in the range of 5∶1-1∶1, the r value in the correlation equation between the weighted average score of the mixed powder and the powder proportion ranged from 0.801 to 0.986, and the linearity was good, indicating that the method of predicting the physical properties of oily powder based on the additive physical properties of traditional Chinese medicine(TCM)powder was feasible. The results of cluster analysis showed that the classification boundaries of the five kinds of TCM materials were clear, and the similarity of the physical fingerprints of powdery and oily materials decreased from 80.6% to 37.2%, which solved the problem of fuzzy classification boundaries of powdery and oily materials due to the lack of representativeness of oily material model drugs. The classification of TCM materials was optimized, laying a foundation for optimizing the prediction model of the prescription of personalized water-paste pills.


Subject(s)
Medicine, Chinese Traditional , Drugs, Chinese Herbal , Powders , Prescriptions
4.
Rev. odontol. UNESP (Online) ; 52: e20230035, 2023. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1530306

ABSTRACT

Introdução: Cimentos endodônticos à base de silicato de cálcio demonstram maior solubilidade em água destilada. Emprego de metodologias alternativas pode auxiliar em melhor compreensão sobre a solubilidade desses materiais. Objetivo: Avaliar o efeito da solução de imersão e do tipo de modelo experimental na solubilidade de cimento pronto para uso Bio-C Sealer. Material e método: Modelos circulares de polietileno ou dentina bovina (n = 16) foram confeccionados. Após inserção do cimento, os espécimes foram mantidos em estufa a 37 °C por 48 horas. Posteriormente, as amostras foram pesadas em balança de precisão para determinação da massa inicial. Na sequência, os espécimes foram imersos em 7,5 mL de água destilada (pH 6,5) ou PBS (pH 7,0) (n = 8) por 28 dias. Após isso, as amostras foram removidas das soluções e pesadas a cada 24 horas até a estabilização da massa final (0,001g). Corpos de prova confeccionados com Bio-C Sealer foram empregados como controle. A solubilidade foi avaliada de acordo com a diferença entre a massa inicial e final em porcentagem. Teste ANOVA Two-Way e teste post-hoc de Tukey foram realizados (α = 0,05). Resultado: Imersão em água destilada proporcionou maior solubilidade em comparação com PBS, independentemente do modelo experimental (p < 0,05). Corpos de prova apresentaram maior solubilidade, seguidos dos modelos de polietileno e dentina imersos em água destilada (p < 0,05). Não houve diferença entre os modelos experimentais imersos em PBS (p > 0,05). Conclusão: Bio-C Sealer apresenta solubilidade significativamente maior em água destilada do que em PBS em todas condições. Modelo experimental empregando dentina bovina e PBS como solução de imersão demonstra diminuir a perda de massa de Bio-C Sealer e pode ser uma alternativa valiosa para avaliar a solubilidade de cimentos biocerâmicos


Introduction: Calcium silicate-based sealers demonstrate greater solubility in distilled water. The use of alternative methodologies can help at better understanding the solubility of these materials. Objective: To evaluate the effect of the immersion solution and the type of experimental model on the solubility of readyto-use Bio-C Sealer. Material and method: Circular models of polyethylene or bovine dentin (n = 16) were made. After insertion of the sealer, the specimens were kept in an oven at 37°C and 95% humidity for 48h. Subsequently, the samples were weighed on a precision balance to determine the initial mass. Next, the specimens were immersed in 7.5 mL of distilled water (pH 6.5) or PBS (pH 7.0) (n = 8) for 28 days. After that, the samples were removed from the solutions and weighed every 24 hours until the final mass stabilized (0.001g). Test specimens made with Bio-C Sealer were used as a control. Solubility was evaluated according to the difference between the initial and final mass in percentage. Two-Way ANOVA test and Tukey post-hoc tests were performed (α=0.05). Result: Immersion in distilled water provided greater solubility compared to PBS regardless of the experimental model (p<0.05). The test specimens showed greater solubility, followed by polyethylene and dentin models immersed in distilled water (p<0.05). There was no difference between the experimental models immersed in PBS (p>0.05). Conclusion: Bio-C Sealer presents significantly greater solubility in distilled water than in PBS under all conditions. Experimental model using bovine dentin and PBS as an immersion solution demonstrates reduction in the mass loss of Bio-C Sealer and can be a valuable alternative for evaluating the solubility of bioceramic sealers


Subject(s)
Cattle , Solubility , Distilled Water , Calcarea Silicata , Analysis of Variance , Dentin , Physical Phenomena , Dental Cements
5.
Rev. odontol. UNESP (Online) ; 52: e20230034, 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1530305

ABSTRACT

Introdução: Materiais reparadores devem apresentar baixa solubilidade. Solução salina tamponada com fosfato (PBS) permite simular condição clínica e interação com dentina pode ser importante para correta avaliação da perda de massa de cimentos biocerâmicos. Objetivo: Avaliou o efeito da imersão em água destilada (AD) ou PBS na solubilidade de Bio-C Repair (BCR, Angelus) ou MTA Repair HP (MTAHP, Angelus) usando modelo de tubo de dentina. Material e método: Tubos de dentina bovina foram confeccionados com 4 mm de comprimento, 1,5 mm de diâmetro interno e 1 mm aproximadamente de espessura de parede. Os espécimes foram imersos em AD por 24h, posteriormente preenchidos com BCR ou MTAHP (n = 14) e armazenados em estufa a 37°C e umidade 95% por 24h. Após serem pesados em balança de precisão para determinação da massa inicial, os corpos de prova foram imersos em AD (pH 6,5) ou PBS (pH 7,0) (n = 7) por 28 dias. Tubos vazios também foram utilizados para o cálculo de perda de massa da dentina (n=4). Após esse período, os espécimes foram pesados até a estabilização da massa final (0,001g). A solubilidade de cada material foi avaliada. Testes estatísticos ANOVA e Tukey foram realizados (α=0,05). Resultado: BCR e MTAHP apresentaram ganho de massa em AD e perda de massa em PBS (p<0,05). Conclusão: A solução de imersão influencia a solubilidade de BCR e MTAHP usando modelo de tubo de dentina. Nova proposta metodológica poderá ser uma alternativa às normas ISO para testar a solubilidade de cimentos biocerâmicos


Introduction: Repair materials must have low solubility. Phosphate buffered saline (PBS) allows simulating clinical condition and interaction with dentin may be important for the correct evaluate of mass loss of bioceramic cements. Objective: To evaluate the effect of distilled water (DW), or PBS immersion on the solubility of Bio-C Repair (BCR, Angelus) or MTA Repair HP (MTAHP, Angelus) using a dentin tube model. Material and method: Bovine dentin tubes with a length of 4 mm, an internal diameter of 1.5 mm and walls thickness of approximately 1 mm were made. The specimens were immersed in DW for 24h, then filled with BCR or MTAHP (n = 14) and stored in an oven at 37°C and 95% humidity for 24h. After being weighed on a precision balance to determine the initial mass, the specimens were immersed in DW (pH 6.5) or PBS (pH 7.0) (n = 7) for 28 days. Empty tubes also were used for calculating the mass loss of the dentin (n=4). After this period, the specimens were weighed until stabilization of the final mass occurred (0.001g). The solubility of each material was evaluated. ANOVA and Tukey statistical tests were performed (α=0.05). Result: BCR and MTAHP showing gain of mass in DW and mass loss in PBS (p<0.05). Conclusion: The immersion solution influenced the solubility of BCR and MTAHP using dentin tube model. The new methodological proposal could be an alternative to ISO standards for testing the solubility of bioceramic cement


Subject(s)
Cattle , Calcarea Silicata , Analysis of Variance , Dental Materials , Dentin , Physical Phenomena
6.
Braz. j. oral sci ; 21: e226262, jan.-dez. 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1354997

ABSTRACT

Aim: To evaluate the impact of a dual-cured adhesive system on the in situ degree of conversion (DC), bond strength (BS) and failure mode (FM) of adhesive interfaces in dentin cavities restored with a bulk-fill resin composite. Methods: 4-mm-deep dentin cavities with a 3.1 C-factor were created in 68 bovine incisors (n = 17 per group). The lightcured (Scotchbond™ Universal) or the dual-cured (Adper™ Scotchbond™ Multi-purpose Plus) adhesive system was applied to the cavities, which were then restored with a bulkfill resin composite (Filtek™ Bulk Fill). In situ DC analysis was performed by means of micro Raman spectroscopy at the top and bottom interfaces. Push-out BS was measured in a universal testing machine after 24-h or 6-month water storage. FM was determined with a stereomicroscope. Data of in situ DC and BS were analyzed by two-way analysis of variance (ANOVA) and Tukey test (p<0.05), while the FM was analyzed descriptively. Results: The groups that received the dual-cured adhesive system showed statistically higher in situ DC and BS than those that received the light-cured adhesive system. Cohesive failure mode was the most frequent in all conditions. Conclusion: In situ DC and BS were influenced by the curing strategies of the adhesive systems with better performance of the dual-cured material


Subject(s)
Aging , Dentin-Bonding Agents , Composite Resins , Polymerization
7.
Article | IMSEAR | ID: sea-219365

ABSTRACT

This study aimed to assess the effect of natural antioxidants on storage time, physical and chemical properties of egg. A total of 200 laying ISA brown birds were distributed into eight dietary groups, each dietary group with 25 birds (5 birds per replicate). They were fed with roselle, black pepper, green tea, combine (roselle + black pepper + green tea) at 0.5 g/kg and 1.0 g/kg in basal diet respectively and a control feed. At the end of eight (8) weeks of feeding trial, twelve eggs were collected from each dietary group (six eggs per dietary group were analyzed for the internal and external properties while the remaining six were stored). Data collected include; Egg shape index, egg weight, shell thickness, membrane weight, yolk index, haugh unit, meat and blood spot, yolk colour, lipid profile, lipid peroxidation and proximate analysis. Data generated were subjected to Analysis of variance using the General Linear Model for factorial within a completely randomized design. The natural antioxidants significantly (P<0.05) improves the proximate composition of the poultry eggs. Both Green tea and Black pepper have significant effect (P<0.05) on the yolk percentage. Black pepper increases (P<0.05) the Haugh unit while it shows to be lower (P>0.05) in the combination of the antioxidants. The inclusion levels of the natural antioxidants on the internal and external quality of egg reveals that there were no significant (P>0.05) differences in the two inclusion level of 0.5 g/kg and 1.0 g/kg of feed but they have numerically higher values in the external parameters and internal parameters. Eggs stored for 4 weeks had the lowest value (P>0.05) for the proximate and lipid profiles, though there are no significant (P>0.05) differences in their values. The fresh eggs show high moisture content (P<0.05) but the value for nitrogen free extract is low (P>0.05) in the fresh eggs. The natural antioxidants improved significantly (P<0.05) the proximate composition of the poultry eggs, with the green tea having the highest value (P<0.05) for Moisture contents and CP, black pepper the highest (P<0.05) for CP Based on the result obtained from this study, the natural antioxidants (black pepper, green tea and roselle) in layers� diet shows significant effects on the physical qualities of egg and the yolk color was also preferred with the inclusion of the natural antioxidants compared to the control. The chemical properties also deteriorate with the storage time. Natural antioxidants are hereby recommended for better and improved chemical qualities of eggs.

8.
J. appl. oral sci ; 30: e20210536, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1375714

ABSTRACT

Abstract Objectives: The purpose of this study is to evaluate, over a simulated 5-year period, the effect of simulated gastric juice alternated with brushing on CAD-CAM monolithic materials considering microhardness, substance loss, flexural strength, and reliability of the materials. Methodology: Blocks from Lava Ultimate (LU), Vita Enamic (VE), IPS Empress CAD (EMP), IPS e.max CAD (EMAX), and Vita Suprinity (VS) were milled into cylinders and sliced into disks. The EMAX and VS were crystallized, and all specimens were polished with silicon carbide papers and allocated as follows: 1) artificial saliva + brushing or 2) simulated gastric juice (0.113% hydrochloric acid (HCl) solution in deionized water, pH 1.2) + brushing, simulating 1, 3, and 5 years of clinical function. Each year of clinical function was simulated by three repetitions of immersion for 3 hours in artificial saliva or simulated gastric juice followed by 1,217 brushing cycles. The microhardness and substance loss were evaluated at baseline (T0) and at each year by using a Vickers hardness tester and an analytical balance. The biaxial flexural strength (BFS) test was performed in a mechanical testing machine at the end of the 5th year. Weibull modulus was calculated from the BFS data. Results: The microhardness of the LU was not influenced by the treatment, whereas that of the other materials, in certain years, was significantly lower in the gastric juice + brushing groups in comparison with artificial saliva + brushing groups. In general, the materials did not present a significant change in microhardness over time, for either of the treatments. The LU alone showed greater substance loss in the gastric juice + brushing groups for every year. In both treatments, the LU, VE, and EMP exhibited a significant increase in the substance loss over time. The treatment did not affect the BFS of the materials. The gastric juice + brushing decreased the reliability of the VE. Conclusions: All materials were somehow impaired by the gastric juice + brushing in at least one of the evaluated parameters, except for the BFS. However, in a deeper analysis, the LU would be the least indicated materials, followed by VE, for patients with eating disorders.

9.
Odontol. Clín.-Cient ; 20(2): 18-24, abr.-maio 2021. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-1369090

ABSTRACT

A escolha errada do sistema cimentante pode levar ao fracasso clínico na cimentação de coroas e próteses parciais fixas. Este trabalho teve como objetivo estudar "in vitro" a espessura de película de seis cimentos odontológicos para fixação de peças protéticas, de três grupos distintos, sendo eles: dois cimentos de fosfato de zinco, dois cimentos de ionômero de vidro convencional e dois cimentos resinosos. Foi realizado a manipulação dos cimentos de acordo com as instruções dos fabricantes e após, interposto 1g de material entre duas placas de vidro polidas e sobre as mesmas um peso de 3 Kg, durante 10 minutos. Estas placas foram medidas com um paquímetro digital antes e após a presa dos materiais. Foi realizada a análise estatística com o teste T Student e com o Teste de Variância ANOVA e foi observado uma menor espessura de película de um cimento de ionômero de vidro perante os outros cimentos testados, com diferenças estatísticas ao nível de 5%. Os autores concluíram que o cimento de ionômero de vidro obteve a menor espessura de película, sendo apropriado para cimentação de coroas e pontes fixas... (AU)


The incorrect choice of the cementing system may lead to clinical failure in the cementation of fixed partial crowns and prostheses. The aim of this study was to study the film thickness of six dental cements for the fixation of prosthetic pieces from three different groups of cement: two zinc phosphate cements, two conventional glass ionomer cement and two resin cements. Handling of the cements was carried out according to the manufacturers' instructions and after 1g of material was placed between two polished glass plates and a weight of 3 kg was placed thereon for 10 minutes. These plates were measured with a digital caliper before and after the prey of the materials. Statistical analysis was performed with the Student T test and the ANOVA Variance Test, and a lower film thickness of a glass ionomer cement was observed compared to the other cements tested, with statistical differences at the level of 5%. The authors concluded that glass ionomer cement had the lowest film thickness and was suitable for cementation of fixed crowns and bridges... (AU)


Subject(s)
Dental Prosthesis , Dental Cements , Prostheses and Implants , Resin Cements , Glass Ionomer Cements
10.
Dent. press endod ; 11(1): 40-45, Jan-Apr2021. Tab, Ilus
Article in English | LILACS | ID: biblio-1348171

ABSTRACT

Objetivo: Testar a hipótese nula de que a orientação das ranhuras superficiais não influencia na vida em fadiga de fios de níquel-titânio (NiTi). Material e Métodos: Segmentos de fio de NiTi (Moreli, Sorocaba/SP, Brasil) medindo 30mm e com diâmetro de 0,40mm foram utilizados. As ranhuras foram criadas em relação à direção longitudinal, em 45 e 90 graus. O fio foi analisado sob microscopia eletrônica de varredura e a rugosidade, quantificada por interferometria. O número de ciclos para a fratura (NCF) foi determinado pelo teste de flexão rotativa. Resultados: A rugosidade entre os grupos de 45 e 90 graus apresentou diferenças estatisticamente significativas (p<0,05). O grupo sem ranhuras apresentou o maior NCF (p<0,05). O grupo com ranhuras em 45 graus apresentou maior NCF, em comparação ao grupo com 90 graus (p<0,05). Conclusões: A direção das ranhuras possui influência na vida em fadiga dos fios de NiTi. O NCF aumenta com a redução do ângulo das ranhuras em relação ao longo eixo do fio, independentemente da profundidade das ranhuras (AU).


Objective: this study tested the null hypothesis that the surface grooves orientation does not influence the NiTi wire cyclic fatigue. Material and methods: Segments of NiTi wire (Moreli, Sorocaba, Brazil) measuring 30mm and with a 0.40mm of diameter were used. Grooves were created in the longitudinal direction, at 45 degrees and 90 degrees. The wire was analyzed with SEM and the roughness was quantified by interferometry. The number of cycles until fracture (NCF) was determined by the cyclic fatigue test. Results: the roughness between 45 and 90 degrees groups presented differences (p<0.05). The group without grooves presented the highest NCF (p<0.05). The group with 45 degrees grooves presented better NCF in comparison to the group with 90 degrees (p<0.05). Conclusions: the direction of the grooves influences the fatigue life. The NCF increases with the reduction of the angle of the grooves in relation to the long axis, regardless of the depth of the grooves (AU).


Subject(s)
Humans , Microscopy, Electron, Scanning , Dental Alloys , Fatigue , Interferometry
11.
Article in English | LILACS-Express | LILACS | ID: biblio-1385707

ABSTRACT

ABSTRACT: This study aims to evaluate the physical, chemical, mechanical and optical properties of Bulk-Fill resin, in relation to the literature and its proper clinical uses. A bibliographic search was performed in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which articles published from 1994 to 2020 were collected. Laboratory studies, case reports, systematic reviews and literature reviews, which were developed in living individuals, were included. Therefore, articles that did not deal with the characteristics of the Bulk-Fill resin and its proper clinical uses were excluded. The use of Bulk-Fill resin has been progressively increasing over the years, presenting good properties, achieving success in clinical performance, ease of handling and thus has become the material of choice for dentists. In addition, its longevity demonstrates durability with mechanical properties and resistance to tooth structure. Bulk - Fill resins have characteristics similar to traditional composite resins, when performed according the usage protocol. With the use of this group of resins in a single increment, possible failures that occur during the restorative procedure can be minimized, such as: less chance of incorporating bubbles and a volumetric contraction with less stress on the interface.


RESUMEN: Este estudio tuvo como objetivo evaluar las propiedades físicas, químicas, mecánicas y ópticas de la resina Bulk-Fill, en relación con la literatura y sus usos clínicos apropiados. Realizamos una búsqueda bibliográfica en las bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en la que se recopilaron trabajos que se publicaron entre 1994 y 2020. Fueron incluidos estudios de laboratorio, informes de casos, revisiones sistemáticas y revisiones de literatura, desarrollados en individuos vivos. Por tanto, se excluyeron los artículos que no trataban las características de la resina Bulk-Fill y sus usos clínicos adecuados. El uso de la resina Bulk-Fill ha ido aumentando progresivamente a lo largo de los años, presentando buenas propiedades, logrando éxito en el rendimiento clínico, facilidad de manejo y, por lo tanto, se ha convertido en el material elegido por los dentistas. Además, su longevidad demuestra durabilidad, con propiedades mecánicas y resistencia a la estructura dental.Las resinas Bulk-Fill tienen características similares a las resinas compuestas tradicionales, cuando se realizan siguiendo el protocolo de uso. Con el uso de este grupo de resinas mono incremental, es posible eliminar el paso de varios incrementos, disminuyendo a su vez el tiempo clínico. Además, se pueden minimizar las posibles fallas que se producen durante el procedimiento de restauración, tales como: menos posibilidades de incorporar burbujas y una contracción volumétrica con menos estrés en la interfaz.

12.
Article in English | LILACS-Express | LILACS | ID: biblio-1385736

ABSTRACT

ABSTRACT: To evaluate Knoop microhardness and diametral compression strength at different polymerization times. A total of 80 cylindrical samples with Filtek resin™ One Bulk Fill were made to perform the in vitro study, using half of total samples (n=40) for each test and divided equally between groups (n=10). All samples were made according to ISO 4049 using 2 mm thickness Teflon matrix and a central orifice with 4 mm diameter. Four different times of light-curing in Standard mode suggested by the light-unit manufacturer were selected, therefore, group 1 samples (G1) were light-cured for 5 seconds; group 2 (G2) for 10 seconds; group 3 (G3) for 15 seconds, and group 4 (G4) for 20 seconds. A radiant display, which means a power in mW/cm2 by time in seconds was expressed in Joules (J). The samples were stored in a dark container with distilled water at a temperature of 37°C for 48 hours before testing. One-way analysis of variance (ANOVA) with T-Test (LSD) of multiple comparisons of the mean values of Knoop hardness and diametral compression strength was performed, with significance index α=0.05. Regarding the Knoop microhardness test, G1 (35.73 ± 6.2) presented the lowest values, followed by G2, while G3 and G4 did not present statistical differences between them. For the diametral compression test, G1 (1387.76 ± 190.51) obtained the lowest value when compared to the other groups. G2, G3, and G4 did not present significant statistical differences. The different polymerization times influenced the Knoop microhardness and the diametral compression strength of Bulk Fill resin.


RESUMEN: El objetivo de este trabajo fue evaluar la microdureza Knoop y la resistencia a la compresión diametral en diferentes tiempos de polimerización. En el estudio realizado in vitro, se analizó un total de 80 muestras cilíndricas con la resina Filtek™ One Bulk Fill, utilizando la mitad (n=40) para cada prueba realizada y dividida en partes iguales entre los grupos (n=10). Todas las muestras se tomaron de acuerdo con ISO 4049 utilizando matrices de teflón de 2 mm de espesor y orificio central con 4 mm de diámetro. Se seleccionó cuatro veces el fotocurado de manera estándar, sugerido por el fabricante. Por lo tanto, las muestras del grupo 1 (G1) se fotopolimerizaron durante 5 segundos; grupo 2 (G2) durante 10 segundos; grupo 3 (G3) durante 15 segundos y grupo 4 (G4) durante 20 segundos. La exposición radiante, que indica la potencia en mW / cm2 a lo largo del tiempo en segundos, se expresó en julios (J). Las muestras se almacenaron en un recipiente oscuro con agua destilada en una estufa a una temperatura de 37°C durante 48 horas antes del ensayo. Se realizó para comparaciones múltiples de los valores medios, análisis de varianza (ANOVA) de un criterio con la prueba T (LSD) tanto de la dureza de Knoop como de la compresión diametral con un índice de significación α=0.05. Con respecto a la prueba de microdureza de Knoop, G1 (35,73 ± 6,2) tuvo los valores más bajos, seguido de G2, mientras que G3 y G4 no mostraron diferencias estadísticas entre ellos. Para la prueba de compresión diametral, G1 (1387.76 ± 190.51) obtuvo el valor más bajo en comparación con los otros grupos. G2, G3 y G4 no presentaron diferencias estadísticamente significativas. Los diferentes tiempos de polimerización influyeron en la microdureza de Knoop y la resistencia a la compresión diametral de la resina compuesta mono incremental.

13.
Braz. dent. j ; 32(1): 42-47, Jan.-Feb. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1180727

ABSTRACT

Abstract New methodologies using micro-CT to evaluate solubility besides dimensional and morphological changes of endodontic materials are proposed. However, there is no standardization in the methods. The aim of this study was to assess the effect of different dimensions of test samples on volumetric change evaluation of different endodontic materials. AH Plus, FillCanal and Sealapex root canal sealers, Biodentine, IRM and MTA root-end filling cements were used in the tests. Samples of each material with a thickness of 1.5 mm and different diameters were manufactured: 6.3, 7.75, and 9.0 mm. The samples were scanned in micro-computed tomography (micro-CT) after setting and after 7 days of immersion in distilled water. The volumetric change was evaluated by means of the difference in the total volume of the specimens before and after immersion. Data were submitted to ANOVA and Tukey tests (p<0.05). The size of the samples did not affect the percentage of volumetric change of the materials (p>0.05). All sample sizes had greater volume loss for Sealapex among the sealers and Biodentine for the cements (p<0.05). In conclusion, Biodentine and Sealapex had the highest volume loss after immersion. Samples with 1.5 mm thickness, and diameters ranging between 6.3 and 9.0 mm can be used to assess the stability of endodontic materials using micro-CT without affecting the percentage of volumetric change.


Resumo Novas metodologias utilizando micro-CT são propostas para avaliar a solubilidade além de alterações dimensionais e morfológicas em materiais endodônticos. No entanto, não há padronização nos métodos. O objetivo deste estudo foi avaliar o efeito de diferentes dimensões de corpos de prova na avaliação da alteração volumétrica de diferentes materiais endodônticos. Os cimentos obturadores AH Plus, FillCanal e Sealapex e os cimentos retrobturadores Biodentine, IRM e MTA foram utilizados nos testes. Foram confeccionadas amostras de cada material com espessura de 1.5 mm e diâmetros diferentes: 6.3, 7.75 e 9.0 mm. As amostras foram escaneadas em microtomografia computadorizada (micro-CT) após a presa e após 7 dias de imersão em água destilada. A alteração volumétrica foi avaliada por meio da diferença no volume total dos corpos de prova antes e após a imersão. Os dados foram submetidos aos testes ANOVA e Tukey (p<0,05). A dimensão das amostras não afetou o percentual de alteração volumétrica dos materiais (p>0,05). Todos os diâmetros de amostra mostraram maior perda de volume para Sealapex entre os cimentos obturadores e Biodentine entre os cimentos retrobturadores (p<0,05). Como conclusão, Biodentine e Sealapex mostraram a maior perda volumétrica após a imersão. Amostras com 1.5 mm de espessura e diâmetros variando entre 6.3 e 9.0 mm podem ser usadas para avaliação da estabilidade de materiais endodônticos utilizando micro-CT, sem influenciar no percentual de alteração volumétrica.


Subject(s)
Root Canal Filling Materials , Oxides , Root Canal Obturation , Materials Testing , Calcium Compounds , Drug Combinations , Epoxy Resins , X-Ray Microtomography
14.
Braz. J. Pharm. Sci. (Online) ; 57: e181079, 2021. tab, graf
Article in English | LILACS | ID: biblio-1350243

ABSTRACT

The aim of the current study was to explore the correlation between physical properties of wet masses and pellet quality by using powdered herbal slices as model drugs. Wet masses with 100 formulations were prepared by taking 20 kinds of powdered herbal slices as model drugs, microcrystalline cellulose as pelletization aid and five levels of added water as liquid binder. Physical properties of the wet masses such as hardness, adhesiveness, springiness, cohesiveness, chewiness, and resilience were measured by a texture analyzer. Meanwhile, the moisture retention capacities (MRC) of powdered herbal slices and wet masses were determined. Particles were classified after they were produced during spheronization. Principal component analysis, factor analysis and classification analysis were performed on the data. Wet masses could be classified into three groups by taking Ha as the first classification index and Ha/Sp as the second classification index. The correct rate of the classification was 91.00%. If Ha value of wet masses was greater than 15610 g, pellets of type ① would form, otherwise, pellets of type ② or type ③ would form based on Ha/Sp value. Then a classification plot of wet masses was developed to predict pellet formation of powdered herbal slices. Meanwhile, the probable mechanism of pellets formation during spheronisation was concluded in this study, which provided useful information to improve pellet quality


Subject(s)
Drugs, Chinese Herbal/analysis , Water/pharmacology , Classification , Methods , Pharmaceutical Preparations/analysis
15.
China Journal of Chinese Materia Medica ; (24): 3753-3763, 2021.
Article in Chinese | WPRIM | ID: wpr-888096

ABSTRACT

Chinese medicinals feature different medicinal parts and enriched components, which makes their powders show obvious microscopic identification characteristics and specific physical properties. On this basis, the commonly used Chinese medicinals can be divided into several categories, such as powdery, fibrous, sugar, oil, and brittle materials, which is of great importance to the research and development of personalized Chinese medicinal preparation technology. However, the existing classification methods are highly subjective and thus difficult to meet the requirements for the development of personalized Chinese medicinal preparations with high quality. In this study, 55 representative Chinese medicinals, such as Dioscoreae Rhizoma and Leonuri Herba, were selected, and the physical properties of their powders were systematically characterized by comprehensive powder tester, torque rheometer, texture analyzer, etc., based on which a data set encompassing physical properties of these powders was built. The typical physical fingerprints of powders from the above 5 categories were established by multivariate statistical analysis. Then, the Chinese medicinals were classified according to the Euclidean distance between each of them and the typical value in the PCA score plot. For those with multiple material properties, whose classification boundary was fuzzy, the proportions of different types of materials were calculated with the combination of Euclidean distance, powder properties, microscopic identification characteristics, and chemical composition, so as to achieve the multivariate quantitative classification of Chinese medicinals. This lays the foundation for the further creation of intelligent personalized Chinese medicinal preparation technology.


Subject(s)
Drugs, Chinese Herbal , Medicine, Chinese Traditional , Powders , Rhizome
16.
China Journal of Chinese Materia Medica ; (24): 1622-1628, 2021.
Article in Chinese | WPRIM | ID: wpr-879070

ABSTRACT

The physical properties of ginkgo leaves extract(GLE) are the critical quality attributes for the control of the manufacturing process of ginkgo leaves preparations. In this study, 53 batches of GLE with different sources from the real world were used as the objects to carry out the research from 3 levels. First, based on micromeritics evaluation method, a total of 29 physical attribute quality parameters in five dimensions were comprehensively characterized, with a total of 1 537 data points. Further, with use of physical fingerprinting technology combined with similarity evaluation, the powder physical properties of 53 batches of GLE showed obvious differences from an overall perspective, and the similarity of the physical fingerprints was 0.876 to 1.000. Secondly, hierarchical clustering analysis(HCA) and principal component analysis(PCA) models were constructed to realize the reliable identification and differentiation of real-world materials produced by GLE from different sources. Multivariate statistical process control(MSPC) model was used to create GLE material Hotelling T~2 and squared prediction error(SPE) control charts. It was found that the SPE score of B_(21) powder exceeded the 99% confidence control limit by 22.495 9, and the SPE scores of A_1 and C_(10) powder exceeded the 95% confidence control limit by 16.099 2, realizing the determination of abnormal samples in the materials of GLE from the production in real world. Finally, the physical quality control method of GLE in the production process of ginkgo leaves preparations was established in this study, providing a reference for the quality control methods of ginkgo leaves preparations in their manufacturing process.


Subject(s)
Drugs, Chinese Herbal , Ginkgo biloba , Medicine, Chinese Traditional , Plant Extracts , Plant Leaves , Powders , Quality Control
17.
Perspect. nutr. hum ; 22(2): 175-188, jul.-dic. 2020. tab
Article in Spanish | LILACS | ID: biblio-1351202

ABSTRACT

Resumen Antecedentes: la palma de mil pesos (Oenocarpus bataua) es una especie promisoria, tanto por sus frutos ricos en aceite de excelente condición como por su especial adaptación a suelos pobres. Objetivo: analizar el perfil de ácidos grasos y propiedades fisicoquímicas del aceite de palma de mil pesos. Materiales y métodos: se analizaron las propiedades fisicoquímicas, el porcentaje de saturación con técnicas del AOAC y el perfil de ácidos grasos mediante cromatografía líquida de gases con detector de ionización de llama (CG-FID). Resultados: el aceite analizado tiene un perfil de ácidos grasos parecido al del aceite de oliva, con la siguiente distribución porcentual de ácidos grasos: palmítico (11,9±1,1), oleico (76,1±1), linoleico (3±0,4), α-linolénico (1,9±0,3), con predominio de grasas monoinsaturadas (77,0±1,0 %), moderado aporte de saturadas (18,1±1,2 %) y bajo de poliinsaturadas (4,9±0,6 %), esto último sería la única limitante para utilizarlo como única fuente de grasa para la preparación de alimentos, por lo demás cumple con la norma colombiana para el aceite de palma alto oleico en cuanto al perfil de ácidos grasos y sus características físicoquímicas. Conclusiones: el aceite estudiado es potencialmente comercializable para el consumo humano y tiene beneficios para la salud cardiovascular de los consumidores.


Abstract Background: The thousand peso palm tree (Oenocarpus bataua) is a promising species, both for its oil-rich fruits of excellent properties and for its unique adaptation to poor soils. Objective: Analyze the fatty acid profile and physicochemical properties of oil from the thousand peso palm tree. Materials and Methods: The physicochemical properties and the percentage of saturation ere found using AOAC techniques, and the fatty acid profile was analyzed by liquid gas chromatography with flame ionization detector (GC-FID). Results: The oil analyzed had a fatty acid profile similar to olive oil, with the following percentage distribution of fatty acids: palmitic (11.9±1.1), oleic (76.1±1), linoleic (3±0.4), α-linolenic (1.9±0.3), with a predominance of monounsaturated fats (77.0±1.0%), moderate contribution of saturated (18.1±1.2%) and low polyunsaturated (4.9±0.6%). Only the polyunsaturated profile would constitute a limitation for use as a sole source of fat for food preparation, otherwise thousand peso palm oil complies with the Colombian standard for high oleic palm oil in terms of the fatty acid profile and its physicochemical characteristics. Conclusions: The oil studied is potentially marketable for human consumption and has cardiovascular health benefits for consumers.


Subject(s)
Palm Oil , Fatty Acids
18.
Braz. dent. j ; 31(5): 523-531, Sept.-Oct. 2020. tab
Article in English | LILACS, BBO | ID: biblio-1132329

ABSTRACT

Abstract Thiourethane additives have been shown to improve properties in several dental polymer applications. The aim of this study was to verify the effect of the addition of thiourethane oligomers and acrylamide or isobornyl-based plasticizers on the physical properties of the denture base acrylic resin polymerized with microwaves. Thiourethane oligomer (TU) was synthetized and added to microwaved acrylic resin in proportions varying between 3 and 14 wt%. Separate experimental groups included the addition of dimethyl acrylamide (DMAM) and isobornyl methacrylate as plasticizers, at concentrations varying from 5 to 20 wt%. Samples were polymerized using microwave energy at 500 Watts for 3 min, deflasked at room temperature, stored in water at 37 °C for 24 h, and evaluated for: linear dimensional change, gloss, Knoop hardness, surface roughness, impact strength, yield strength, elastic modulus, toughness, yield strength, viscosity, glass transition temperature and network heterogeneity, and water sorption/solubility. Data were analyzed with ANOVA/Tukey's post-hoc test (a=5%). The addition of TU led to properties that were similar or worse than the materials to which it was not added, except for dimensional stability. The impact on properties was statistically significant for all materials above 20% addition of TU. The addition of DMAM at 5 wt% or isobornyl methacrylate at 10 wt% improved yield strength and modulus, but increased water sorption and solubility. Except for dimensional stability, the addition of thiourethane oligomers to acrylic denture base materials compromised most tested properties. The use of DMAM and isobornyl methacrylate improved properties for selected compositions.


Resumo Aditivos de tiouretano demonstraram melhorar propriedades de polímeros em diversas aplicações. O objetivo deste estudo foi verificar o efeito da adição de oligômeros de tiouretano, monômeros de acrilamida ou baseados em funcionalidade isobornil na propriedades físicas de bases de dentadura de acrílico polimerizadas em micro-ondas. O oligômero de tiouretano (TU) foi sintetizado e adicionado à resina acrílica em proporções variando de 3 a 14% em peso. Dimetil acrilamida (DMAM) e isobornil metacrilato (IBMA) foram adicionados em formulações separadas como plastificantes em concentrações variando de 5 a 20% em peso. As amostras foram polimerizadas usando energia de micro-ondas (500 Watts oor 3 min), desincluídas da mufla a temperature ambiente, armazenadas em água a 37°C por 24 h, e submetidas aos testes de: alteração dimensional linear, brilho, dureza Knoop, rugosidade superficial, resistência ao impacto, tensão normal de escoamento, módulo de elasticidade, tenacidade, viscosidade, temperatura de transição vítrea e heterogeneidade da rede polimérica, além de sorção de água e solubilidade. Os dados foram analisados com ANOVA e teste de Tukey (a=5%). A adição de TU não afetou ou diminuiu todas as propriedades, exceto pela estabilidade dimensional. O impacto nas propriedades foi estatisticamente significante para todos os materiais em concentrações acima de 20% de TU. Isso pode ser explicado por um encurtamento das cadeias e diminuição do empacotamento das cadeias lineares do PMMA. A adição de 5% de DMAM ou 10% de isobornil metacrilato melhoraram a tensão de escoamento e o módulo, mas aumentaram a sorção de água e solubilidade. Exceto pela estabilidade dimensional, a adição de oligômeros de tiouretano à bases de dentatura compostas por resina acrílica prejudicou todas a propriedades testadas. O uso de DMAM e isobornil metacrilato melhorou as propriedades para composições selecionadas.


Subject(s)
Denture Bases , Microwaves , Surface Properties , Materials Testing , Polymethyl Methacrylate , Dental Materials , Polymerization
19.
Braz. dent. j ; 31(5): 499-504, Sept.-Oct. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132336

ABSTRACT

Abstract This study evaluated by micro-computed tomography (μCT) the filling ability in curved root canals, besides the flow of AH Plus (AHP) and Neo MTA Plus (NMTAP) sealers using different methodologies. Mandibular molars mesial roots with two root canals and degree of curvature between 20° and 40° were selected. The specimens were prepared with the ProDesign R system up to size 35.05 and were filled with the sealers by a continuous wave of condensation technique, Thermo Pack II (n=12). The teeth were scanned using μCT after root canal preparation and obturation. The volumetric percentage of filling material and voids were calculated. Flow was evaluated based on ISO 6876/2012 (n=10). Flow and filling were also evaluated in μCT using a glass plate with a central cavity and four grooves from the central cavity (n=6). Flow was linearly calculated into the grooves. The central cavity filling (CCF) and lateral cavity filling (LCF) were calculated in mm³. Data were submitted to non-paired t test with a significance threshold at 5%. The percentage of filling and voids between the root canals filled with AHP or NMTAP was similar (p>0.05). NMTAP presented the lowest flow in conventional test (p<0.05). Using μCT, sealers had similar CCF, LCF and linear flow (p>0.05). In conclusion, NMTAP and AHP had similar filling ability in curved mesial root canals of mandibular molars without presence of isthmus. Although AHP presented better flow than NMTAP using ISO methodology, there was no difference between these materials regarding volumetric filling when evaluated by μCT.


Resumo Este estudo avaliou por microtomografia computadorizada (μCT) a capacidade de preenchimento de canais radiculares curvos, além do escoamento dos cimentos AH Plus (AHP) e Neo MTA Plus (NMTAP) utilizando diferentes metodologias. Foram selecionadas raízes mesiais de molares inferiores com dois canais radiculares e grau de curvatura entre 20° e 40°. As amostras foram preparadas com o sistema ProDesign R até o tamanho 35.05 e foram obturadas com os cimentos por uma técnica de onda contínua de condensação, Thermo Pack II (n=12). Os dentes foram escaneados usando μCT após o preparo e obturação do canal radicular. A porcentagem volumétrica de material de preenchimento e vazios foram calculados. O escoamento foi avaliado com base na norma ISO 6876/2012 (n=10). O escoamento e o preenchimento também foram avaliados em μCT usando uma placa de vidro com uma cavidade central e quatro canaletas a partir da cavidade central (n=6). O escoamento foi calculado linearmente nas canaletas. O preenchimento da cavidade central (PCC) e o preenchimento da cavidade lateral (PCL) foram calculados em mm³. Os dados foram submetidos ao teste t não pareado com nível de significância de 5%. A porcentagem de preenchimento e vazios entre os canais radiculares preenchidos com AHP ou NMTAP foi semelhante (p>0,05). NMTAP apresentou o menor escoamento no teste convencional (p<0,05). Utilizando μCT, os cimentos apresentaram PCC, PCL e escoamento linear semelhantes (p>0,05). Em conclusão, NMTAP e AHP apresentaram capacidade de preenchimento semelhante em canais mesiais curvos de molares inferiores sem presença de istmo. Embora o AHP tenha apresentado melhor escoamento que o NMTAP usando a metodologia ISO, não houve diferença entre esses materiais em relação ao preenchimento volumétrico quando avaliados por μCT.


Subject(s)
Root Canal Filling Materials , Dental Pulp Cavity/diagnostic imaging , Root Canal Obturation , Root Canal Preparation , X-Ray Microtomography , Gutta-Percha
20.
Braz. dent. j ; 31(3): 252-256, May-June 2020. tab
Article in English | LILACS, BBO | ID: biblio-1132297

ABSTRACT

Abstract The purpose of this study was to investigate and to compare the physical-mechanical properties of a resin-modified calcium silicate material (TheraCal LC), used for pulp-capping, to MTA (Angelus) and a calcium hydroxide cement (Dycal). Specimens of each material (n=12) were prepared in Teflon molds (3.58 mm x 3 mm) and measured before and after immersion in distilled water for 24 h and 30 days to evaluate the dimensional change. The same specimens were submitted to compressive strength test on a Universal Testing Machine (Instron) (1 mm/min). Root canals were filled with the cements (n=8), and after 24 h, the bond strength (push-out test) to dentin was also assessed on a Universal Testing Machine (1 mm/min). Eight additional specimens of TheraCal LC were prepared to evaluate the bond strength immediately after light curing. Data were analyzed using One-Way ANOVA, and Tukey or Bonferroni post hoc tests (p<0.05). Percentage expansion of TheraCal LC was above the Specification No. 57 of ANSI/ADA, in both periods. The dimensional change for TheraCal LC was higher than MTA in 24 h and 30 days; and Dycal in 30 days (p<0.05). TheraCal LC had higher compressive and bond strength to dentin in comparison with MTA and Dycal (p<0.05). Although TheraCal LC expanded more than the ANSI/ADA recommendation, its compressive and push-out bond strength to dentin were satisfactory and superior to MTA and Dycal.


Resumo O objetivo deste estudo foi investigar e comparar as propriedades físico-mecânicas de um material à base de silicato de cálcio modificado por resina (TheraCal LC) ao MTA (Angelus) e um cimento de hidróxido de cálcio (Dycal). Espécimes de cada material (n=12) foram fabricados em moldes de Teflon (3,58 mm x 3 mm) e medidos antes e após imersão em água destilada por 24 h e 30 dias para avaliar a alteração dimensional. Os mesmos espécimes foram submetidos ao teste de resistência à compressão em uma Máquina Universal de Testes (Instron) (1 mm/min). Canais radiculares foram preenchidos com os cimentos (n=8), e após 24 h, a resistência de união (teste de push-out) também foi avaliada em uma Máquina Universal de Testes (1 mm/min). Oito amostras adicionais de TheraCal LC foram preparadas para avaliar a resistência de união imediatamente após a fotoativação. Os dados foram analisados utilizando os testes ANOVA de 1-fator e Tukey; ou Bonferroni (p<0,05). A expansão percentual do TheraCal LC ficou acima da Especificação No. 57 do ANSI/ADA, em ambos os períodos. Os valores de alteração dimensional para TheraCal LC foram maiores que MTA em 24 h e 30 dias; e Dycal em 30 dias (p<0,05). TheraCal LC apresentou maior resistência à compressão e união à dentina em comparação ao MTA e Dycal (p<0,05). Embora TheraCal LC tenha expandido mais que a recomendação da ANSI/ADA, sua resistência à compressão e de união à dentina foram satisfatórias e superiores ao MTA e Dycal.


Subject(s)
Dental Pulp Capping , Pulp Capping and Pulpectomy Agents , Oxides , Materials Testing , Silicates , Calcium Compounds , Aluminum Compounds , Drug Combinations
SELECTION OF CITATIONS
SEARCH DETAIL